skip to Main Content

Below is a list of recommended curing times for EnvisionTEC materials in the PCA 4000 curing apparatus.

Curing times are subject to change.

*Testing in progress. Curing times are subject to change.

DENTAL

Material Time (H:MM:SS) Temp. Power
E-AquaModel 0:02:00 20˚ C 100%
*Flexcera Smile 0:15:00

0:02:30

60˚ C

60˚ C

100%

100% after polishing

*Flexcera Base 0:15:00

0:02:30

60˚ C

60˚ C

100%

100% after polishing

E-Guard 2.0 0:01:00 20˚ C 35%
E-Guide 2.0 0:01:00 20˚ C 35%
*E-Guide Tint 0:30:00 60˚ C 100%
E-Model (Light, Beige, HS) 0:01:00 20˚ C 100%
E-Orthoshape 0:01:00 20˚ C 100%
E-Partial 0:04:00 20˚ C 100%
*NextDent C&B MFH 0:04:00 35˚ C 100%
*NextDent Denture 3D+ 0:02:00 20˚ C 100%
*NextDent Gingiva Mask 0:03:00 60˚ C 100%
*NextDent Ortho IBT 0:01:00 20˚ C 100%

INDUSTRIAL

Material Time (H:MM:SS) Temp. Power
E-3172 First cycle: 0:06:00 60˚ C 100%
Second cycle: 0:30:00 60˚ C 100%
E-3840 0:01:00 60˚ C 39%
E-3843 First cycle: 0:06:00 60˚ C 100%
Second cycle: 0:30:00 60˚ C 100%
E-3860 0:06:00 60˚ C 68%
Convection oven: 0:30:00 160˚ C N/A
E-5015 0:20:00 60˚ C 100%
E-IND147 1:30:00 60˚ C 100%
Convection oven: 3:00:00 170˚ C N/A
E-IND402 (Black, Gray) 1:30:00 60˚ C 100%
E-IND406 1:00:00 60˚ C 100%
Convection oven: 2:00:00 140˚ C N/A
E-Rigid Form (Charcoal, Amber) 0:04:00 20˚ C 100%
E-Rigid PU 0:05:00 60˚ C 100%

JEWELRY

Material Time (H:MM:SS) Temp. Power
Easy Cast 2.0 0:30:00 60˚ C 100%
EC-3000 0:10:00 60˚ C 100%
EC-500 0:30:00 60˚ C 100%

Was this article helpful?

×Close search
Search
Back to top